The AMP-FL56XX-OB/OP series PDFA is a versatile O-band fiber amplifier, primarily designed for network applications such as data centers, access/metro networks. The amplifier can be used in WDM configuration, and its amplification performance does not depend on signal formats, i.e. ranging from legacy 100 Mbps IM-DD signal to 100GBASE-LR4 signal and 400GBASE-LR8 PAM4 signal. Being independent on signal formats, amplifier replacement is not necessary when transmitters/receivers are upgraded. This amplifier can be used for network monitoring (e.g. deep packet inspection) as it can amplify small signal from a network TAP. Also available in bench-top and OEM module format.
Product Type : Rack Mount
Operating Wavelength:1280 nm ~1320 nm
Product Number | Operating WaveLength (nm) | Nominal WL (nm) | Output Power (dBm) (*1) | Gain (dB) (*2) | NF (dB) (*2) | PER (dB) | IN/OUT Fiber | Standard Connector | IN/OUT Isolator | Std. Dimension (H x W x D, mm) (*3) |
---|---|---|---|---|---|---|---|---|---|---|
AMP-FL5601-OB-13 | 1280 to 1320 | 1310 | ≥ +13 | Typ. 18 | ≤ 7 | N/A | SMF (*4) | SC/PC | Built In | 43 x 440 x 403 |
AMP-FL5601-OB-16 | 1280 to 1320 | 1310 | ≥ +16 | Typ. 24 | ≤ 7 | N/A | SMF (*4) | SC/PC | Built In | 43 x 440 x 403 |
AMP-FL5601-OB-20 | 1280 to 1320 | 1310 | ≥ +20 | Typ. 40 | ≤ 7 | N/A | SMF (*4) | SC/PC | Built In | 43 x 440 x 403 |
AMP-FL5611-OP-10 | 1280 to 1320 | 1310 | Typ. +8 | ≥ 10 | ≤ 6.7 | N/A | SMF (*4) | SC/PC | Built In | 43 x 440 x 403 |
AMP-FL5611-OP-15 | 1280 to 1320 | 1310 | Typ. +10 | ≥ 15 | ≤ 6.7 | N/A | SMF (*4) | SC/PC | Built In | 43 x 440 x 403 |
(*1) Input Power: 0 dBm @ Nominal Wavelength
(*2) Input Power: -30 dBm @ Nominal Wavelength
(*3) Does not include protrusions
(*4) G.652 compliant (e.g. SMF28)
Attribute | Specification |
---|---|
Control Mode | ACC (Auto Current Control) and ALC (Auto Light Control) |
Monitor & Alarm | Input power / Output power / Pump LD current / Pump LD temperature / Case temperature / Power-Supply-Unit voltage (alarm only) / Fan Rotation (alarm only) |
Safety Function | Interlock with input level Alarm |
Remote Interface | RS-232C / Relay terminal for alarm |
Temperature | Operation : 0 to 40 ºC / Storage : -10 to 60 ºC |
Power Supply | AC 100 to 240 V (50/60 Hz), Redundant and Hot-Swap |
Humidity | 5 to 80 % RH (non-condensing) |
Other Environmental Conditions | Indoor use / Overvoltage category: II / Altitude: |
Safety Standards | IEC 60825-1 (JIS C 6802) / CE marking (EN 61010-1 / EN 61326-1) |
Number | Option |
---|---|
-011 | FC/PC Connector |
-012 | FC/APC Connector |
-014 | SC/APC Connector |
-019 | Other Cusomized Connector |
-023 | DC 48V Hot Swap Power Supply |
-029 | Other Cusomized Power Supply |
-092 | Ethernet Interface |
-093 | Reflection Monitor and Interlock |
-151 | Front Control Panel and Display |