JAPANESE / ENGLISH
The AMP-FL5701-B4 & 5701-I4 are designed to simultaneously amplify 4 CWDM channels from 1531 to 1591 nm. The AMP-FL5701-B4 is placed immediately after a CWDM transmitter as a booster amplifier, and the AMP-5701-I4 is used as an in-line amplifier. The amplifiers can be used with any CWDM transmitters, as the amplification performance does not change with modulation speed and format.
Product Type : Rack Mount
Operating Wavelength:1530 nm ~1590 nm
Product Number | Operating WaveLength (nm) | Nominal WL (nm) | Output Power (dBm/ch) (*1) | Gain (dB) (*2) | NF (dB) (*2) | PER (dB) | IN/OUT Fiber | Standard Connector | IN/OUT Isolator | Std. Dimension (H x W x D, mm) (*3) |
---|---|---|---|---|---|---|---|---|---|---|
5701-B4 | 1531 ± 6.5 1551 ± 6.5 1571 ± 6.5 1591 ± 6.5 | 1531 1551 1571 1591 | ≥ +10 | N/A | N/A | N/A | SMF (*4) | SC/PC | Built In | 43 x 440 x 403 |
5701-I4 | 1531 ± 6.5 1551 ± 6.5 1571 ± 6.5 1591 ± 6.5 | 1531 1551 1571 1591 | ≥ +0 | N/A | N/A | N/A | SMF (*4) | SC/PC | Built In | 43 x 440 x 403 |
(*1) Input Power: 0 dBm/ch (5701-B4) and -18 dBm/ch (5701-I4), all four channels amplified simultaneously
(*2) Not specified
(*3) Does not include protrusions
(*4) G.652 compliant (e.g. SMF28)
Attribute | Specification |
---|---|
Control Mode | ACC (Auto Current Control) |
Monitor & Alarm | Input power / Output power / Pump LD current / Pump LD temperature / Case temperature / Power-Supply-Unit voltage (alarm only) / Fan Rotation (alarm only) |
Safety Function | Interlock with input level Alarm |
Remote Interface | RS-232C / Relay terminal for alarm |
Temperature | Operation : 0 to 40 ºC / Storage : -10 to 60 ºC |
Power Supply | AC 100 to 240 V (50/60 Hz), Redundant and Hot-Swap |
Humidity | 5 to 80 % RH (non-condensing) |
Other Environmental Conditions | Indoor use / Overvoltage category: II / Altitude: |
Safety Standards | IEC 60825-1 (JIS C 6802) / CE marking (EN 61010-1 / EN 61326-1) |
Number | Option |
---|---|
-011 | FC/PC Connector |
-012 | FC/APC Connector |
-014 | SC/APC Connector |
-019 | Other Cusomized Connector |
-023 | DC 48V Hot Swap Power Supply |
-029 | Other Cusomized Power Supply |
-092 | Ethernet Interface |
-093 | Reflection Monitor and Interlock |
-151 | Front Control Panel and Display |